Dental Equipment Online Store
  • ABOUT US
  • STORE
    • Apixia Dental
    • Air Techniques
    • Acteon Satelec
    • Carestream dental
    • Denterprise International
    • Ivoclar Vivadent
    • PLAMENCA
    • SCISCAN
    • VELOPEX
    • Vident
  • PRIVACY POLICY
  • PAYMENT METHODS​
  • CONTACT

Ivoclar Vivadent Programat P510 Ceramic Furnace

$3,980.00
Add to Cart
Description:
The Programat P510 combines high-tech and modern design in a very efficient and user-friendly furnace.
The intelligent Programat with infrared technology speeds up the firing process up to 25 per cent and enhances the firing results. The size or the number of restorations in the firing chamber is irrelevant. The new thermal imaging camera automatically controls the predrying and closing process.
The Programat P510 is operated by means of the large 7-inch colour touch screen and the proven membrane-sealed keypad. In addition to the many Ivoclar Vivadent programs, which are coordinated with materials such as IPS e.max, IPS d.SIGN, IPS InLine and IPS Empress, the furnace features 500 individual programs.
The QTK2 muffle technology represents a further innovation. It is responsible for ensuring homogeneous heat distribution and a prolonged life cycle of the heating element. Finally, the new vacuum pump control system with double valve technology ensures noiseless and power-saving operation.
Advantages

-Integrated infrared thermal camera ensures an optimum predrying process
-Large colour touch screen and proven membrane-sealed keypad
-QTK2 muffle technology with SiC bottom reflector
-Automatic double-range temperature calibration (ATK2)
-Remote diagnostics via Internet, e-mail and data log files
-OSD display of operating and progress status
-Power-saving technology
-Programat WLAN Kit for wireless data transfer (software updates, PrograBase x10)
-Selection of three different operating modes (normal, protected, production)
-Large cooling tray
-Multimedia functions (video player, MP3 player, photo viewer)
-Integrated timer

Ivoclar Vivadent Programat P310 Ceramic Furnace

$2,190.00
Add to Cart
Description:
With its compact design, the Programat P310 focuses on the essentials and is therefore the optimal furnace for the daily lab routine.
Thanks to the new colour touch screen and the proven membrane-sealed keypad, this furnace has become even simpler to operate than those of the previous generation P300.
The furnace is equipped with numerous Ivoclar Vivadent programs, which are coordinated with materials such as IPS e.max, IPS d.SIGN, IPS InLine and IPS Empress, to ensure immediate use of the furnace without programming. Depending on the scope of the application, the user can select between different operating modes (normal, protected and production).
Furthermore, the Programat P310 is equipped with the QTK2 muffle technology, which is responsible for the homogeneous heat distribution in the firing chamber, leading to optimum firing results and a prolonged life cycle of the heating element. Finally, the new vacuum pump control system with double valve technology ensures noiseless and power-saving operation.
Advantages:

Colour touch screen and proven membrane-sealed keypad
Easy operation thanks to large icons
QTK2 muffle technology with SiC bottom reflector
Power-saving technology
OSD display
Remote diagnostics via Internet, e-mail and data log files
Selection of three different operating modes (normal, protected, production)
Integrated tong holder
300 individual firing programs
Double valve vacuum technology

Ivoclar Vivadent Programat P700/G2 Ceramic Furnace

$2,525.00
Add to Cart
The Programat P700 of the second generation is an absolute highlight among ceramic furnaces.
The newly added features include the integrated Power Saving Technology, which reduces the power consumption in the stand-by mode by up to 40%, and the modern user interface with coloured icons. Additionally, the furnace is equipped with voice output. The user obtains useful information in 13 different languages. The integrated Cooling Shock Protection (CSP) with a specially developed opening and cooling process prevents the formation of tension and cracks within the ceramic.

The Programat P700 can display coloured digital patient and tooth images and features an integrated MP3 player. The optical operating status display informs the user about the current status of the furnace even from a large distance. The furnace is equipped with the QTK heating muffle technology, which enables optimum firing results.
Advantages

The QTK muffle technology enables homogeneous heat irradiation and optimum firing results.
Automatic temperature calibration (ATK2 double-range calibration)
OSD operating status display
Colour display with touch function and tried-and-tested membrane-sealed keypad
120 preset Ivoclar Vivadent programs and 700 individual programs
CSP function (Cooling Shock Protection)
The TSP function (Thermo Shock Protection) prevents thermal shock of the ceramic if the furnace is heated too quickly.
4 USB connections, Ethernet interface, integrated card reader for image files
Connector socket for stereo speakers

IvoBase Injector Injection Systems

$5,589.00
Add to Cart
Description:
IvoBase Injector permits a fully automated, controlled injection and polymerization procedure of special PMMA resins which are coordinated with the system. The chemical shrinkage of the resin is entirely compensated during polymerization ? thanks to the patented temperature control in the flask and the heater. This enables the fabrication of denture bases featuring high accuracy of fit and precision. The injector has been especially developed for the IvoBase material and permits excellent restorations. The IvoBase Injector can also be used for the tried-and-tested SR Ivocap material.
Advantages:

All-in-one" injector, quick and easy setting into operation possible
Controlled polymerization shrinkage for optimal accuracy of fit
No water and compressed air connection necessary (plug and play)
Compact, modern and ergonomic design; requires only a small space
OSD indicator: current operating status visible from a great distance
RMR key for a clear reduction of the residual monomer content
USB port for software updates via PC/Internet
Direct flask heating without water bath permits polymerization without annoying steam
High maintenance friendliness and easy replacement of the heating elements due to the removable cover
Versatile injector with various Ivoclar Vivadent and reserve programs

Ivoclar Vivadent Programat CS2 Ceramic Furnace

$3,980.00
Add to Cart
Description:
The second generation of the Programat CS series is the ideal ceramic and crystallization furnace for dentists.
The device has been specially developed for the crystallization of IPS e.max CAD restorations. The Programat CS2 is easily operated by means of the new colour touch screen and the proven membrane-sealed keypad. It is furthermore equipped with 20 individual programs as well as predefined Ivoclar Vivadent programs, such as the Speed program, which crystallizes IPS e.max CAD restorations in less than 15 minutes.

The QTK2 muffle technology is responsible for even more homogeneous heat distribution in the firing chamber, leading to optimum firing results and a prolonged life cycle of the heating element. Additionally, the new vacuum pump control system with double valve technology ensures noiseless and power-saving operation of the vacuum pump.
Advantages:
Colour touch screen and proven membrane-sealed keypad
QTK2 muffle technology with SiC bottom reflector
Easy operation; specially developed for use in the dental practice
Automatic double-range temperature calibration (ATK2)
Remote diagnostics via Internet, e-mail and data log files
Software updates via USB flash drive
Power-saving technology
OSD display
Integrated tong holder
Double valve vacuum technology


Ivoclar Vivadent Programat S1 Sintering Furnace

$5,690.00
Add to Cart
Description:
The Programat S1 is a light-weight and compact sintering furnace for the sintering of frameworks made of IPS e.max ZirCAD and other ZrO2 materials. New with software-version V2.0: “75 minutes is all it takes”!
With the Programat S1, long sintering processes are a thing of the past. It sinters single-tooth frameworks of zirconium oxide material in 75 minutes and zirconium bridge frameworks up to four units in 90 minutes. Conventional sinter furnaces usually take five to eight hours for this process. What does a short sintering process mean for the laboratory? Crowns and bridges with a zirconium oxide framework can be fabricated in one work day (including veneer). The short sintering process does not jeopardize the high material strength and accuracy of fit of the restoration, as scientific investigations have shown. Furthermore, less power is used.
Advantages

Single-tooth frameworks can be sintered in 75 minutes and bridge frameworks in 90 minutes
Speed programs for full anatomic restorations with higher translucency
Simple and language-independent operation thanks to the proven combination of membrane-sealed keypad and graphic display
Power Saving Technology: Compared with conventional sintering furnaces, up to 64% of the energy is saved with one sintering process
Compact design based on the Programat platform
Only 28 kg
Calibration possibility
OSD operating status display
Comfortable loading of the sintering chamber thanks to the furnace head tilting upwards
Removable furnace head for maintenance purposes
USB connection – easy software updates
Remote control via PC/laptop by means of PrograBase2 software

Programat EP 5010

$5,190.00
Add to Cart
Programat EP 5010
The Programat EP 5010 combines high-tech and modern design in a very efficient and user-friendly furnace. In addition, the Programat EP 5010 is optimally coordinated with Ivoclar Vivadent press ceramic materials such as IPS e.max Press.
The Programat EP 5010 is a premium combination furnace of the latest generation of the Programat series and may be used as both a press and a ceramic furnace. This highly innovative, efficient and user-friendly furnace model optimally combines sophisticated design and advanced technology.
The Programat EP 5010 features an integrated thermal imaging camera. The Programat Infrared Technology measures the exact temperature at the surface of the fired object or the investment ring. By means of the temperature control of the preheated investment ring, the preheating furnace and the press furnace can be optimally coordinated with each other. If the investment ring is preheated insufficiently, a warning is automatically displayed. If the furnace is used in the firing mode, the camera automatically controls the closing and predrying process. Thus, the integrated infrared technology provides a wealth of new possibilities which increase the furnace’s user-friendliness, process reliability and efficiency.
Programat EP 5010_PS_001 - Copy
The Programat EP 5010 can be intuitively operated by means of the large 7-inch colour touch screen and the proven membrane-sealed keypad. In addition to the many Ivoclar Vivadent programs, which are specially coordinated with materials such as IPS e.max Press, the furnace features 500 individual firing programs and 20 individual press programs.
The new QTK2 heating muffle in combination with the SiC bottom reflector ensures homogeneous heat distribution in the firing chamber. As a result, the investment ring is preheated more evenly and reliably. Furthermore, these features enable the user to press difficult-to-press objects, e.g. with very thin marginal areas, and to achieve even higher quality results.
The electronic press drive with force sensor ensures the precise control of the press plunger in the micrometre range. The integrated Crack Detection System (CDS) immediately interrupts the press process if a crack in the investment ring occurs. Therefore, restorations are optimally protected.

Advantages:
Programat Infrared Technology recognizes the size and controls the temperature of the investment ring and ensures optimum predrying processes.
QTK2 muffle technology with SiC bottom reflector for homogeneous heat distribution.
Modern operating concept featuring a large 7-inch colour touch screen and the proven membrane-sealed keypad for easy and intuitive operation.
Optical status and progress display (OSD) informs the user about the current status of the furnace.
Electronic press drive with force sensor produces high-quality press results. No compressed air connection required.
Crack Detection System detects cracks in the investment ring.
Easy and automatic temperature calibration at two reference points (ATK2).
Simple software update via USB flash drive or WLAN.
Remote diagnosis function via data file for optimum support by a service centre.
Integrated multimedia functions (photo viewer, video and MP3 player).
Power Saving Technology for power-saving operation.
USB and Ethernet interfaces, SD card reader

Programat EP 3010

$4,890.00
Add to Cart
The Programat EP 3010 is characterized by cost effectiveness and high-quality press and firing results. In addition, the Programat EP 3010 is optimally coordinated with Ivoclar Vivadent press ceramic materials such as IPS e.max Press.
In comparison to its predecessor model EP 3000, the operation of the Programat EP 3010 has become even simpler due to the new colour touch display, the modern icons, the intuitive menu-based navigation and the proven membrane-sealed keypad.
The new QTK2 heating muffle in combination with the SiC bottom reflector ensures homogeneous heat distribution in the firing chamber. As a result, the investment ring is preheated more evenly and reliably. Furthermore, these features enable the user to press difficult-to-press objects, e.g. with very thin marginal areas, and to achieve even higher quality results.
The electronic press drive with force sensor ensures the precise control of the press plunger in the micrometre range. The integrated Crack Detection System (CDS) immediately interrupts the press process if a crack in the investment ring occurs. Therefore, restorations are optimally protected.

Advantages:
Programs are optimally coordinated with Ivoclar Vivadent materials.
QTK2 muffle technology with SiC bottom reflector for homogeneous heat distribution.
Colour touch screen and proven membrane-sealed keypad for easy operation.
Electronic press drive with force sensor produces high-quality press results. No compressed air connection required.
Crack Detection System detects cracks in the investment ring.
Easy and automatic temperature calibration at two reference points (ATK2).
Simple software update via USB flash drive.
Remote diagnosis function via data file for optimum support by a service centre.
Broad range of programs: 300 individual firing and 20 individual press programs.
Power Saving Technology for power-saving operation..

Ivoclar Vivadent Articulator Stratos 100

$535.00
Add to Cart
The Stratos 100 is a simple average-value articulator with convenient handling. Ivoclar Vivadent teeth can be set up quickly and easily in conjunction with the setting-up template.
The ergonomically designed Stratos 100 with the spacious column construction enables easy and efficient handling. It is the ideal articulator to set up Ivoclar Vivadent teeth according to the Biofunctional Prosthetic System (BPS) and other popular set-up methods.

Advantages
Easy handling
Centric locking catch for quick centric fixation 
Separable upper and lower frame 
Freely advancing joint axis
Ergonomic design with ample working space
Practice-oriented accessories assortment
Compatible with split-cast system and systems for coordination (Adesso-Split, Quick-Split)
45° incline support
Technical data
Bonwill triangle 108 mm
Balkwill angle 15°
Protrusion path angle 30°
Retrusion path angle 35°
Bennett angle 0°-30°
Centric fixation that can be activated

Ivoclar Vivadent Articulator Stratos 200

$736.00
Add to Cart
The Stratos 200 is a biofunctional, semi-adjustable articulator with a variety of adjustment possibilities provided by the exchangeable joint inserts. It has been specifically designed for use in fixed and removable denture prosthetics.
The ergonomic incline supports offer users ample space and provide optimum working conditions. The state-of-the-art design and high quality of the apparatus set new standards in articulator technology.
Advantages
Easy handling
Centric fixation for exact set-up position
Upper and lower frame can be easily separated
Optimized joint mechanics with exchangeable Bennet and protrusion inserts as well as retrusive movement
Choice between fixed or swivel joint axis
Ergonomic design with adequate working space
ISS screw for the immediate side shift
Practice-oriented range of accessories
Compatibility with split-cast systems and systems for coordination (Adesso-Split, Quick-Split)
Technical data
Bonwill triangle 108 mm
Balkwill angle 15°
Protrusion path angle 0°–60°
Bennett angle 15°, 30°
Retrusion path angle 35°

Ivoclar Vivadent Articulator Stratos 300

$1,050.00
Add to Cart
As a modern precision articulator, the Stratos 300 offers a wealth of individual adjustment possibilities. With numerous variations, it provides the ideal basis for the precise simulation of functions for sophisticated and exacting dental lab work.
The Stratos 300 articulator is suitable for demanding and complex dental restorations for which the joint angles have to be individually set. Its ergonomic design with spacious column construction enables easy and efficient handling.
Advantages
Possibility of individual and average-value model orientation
Easy handling
Centric locking catch for accurate operation
Separable upper and lower frame 
Freely advancing guided joint axis
Ergonomic design with ample working space
ISS screw for side-shift movement
Practice-oriented accessories assortment
Compatible with split-cast systems and systems for coordination (Adesso-Split, Quick-Split)
45° incline support
Technical data
Bonwill triangle 108 mm
Balkwill angle 15°
Protrusion path angle 0°–60°
Retrusion path angle 35°
Bennett angle 0°–30°
Side Shift 0–1.5 mm
Protrusion movement 0–4 mm
Centric fixation can be activated

Articulator programming
For the recording and determination of the individual patient parameters with regard to articulator programming, we recommend using the following electronic TMJ movement measuring systems which support the Stratos articulators. Use one of the following links for further information:
Stratos with the CADIAX Compact System
Stratos with the Zebris JMA System
Stratos with the ARCUSdigma System
Stratos with the Condylocomp LR3 System
Powered by Create your own unique website with customizable templates.